{"title":"Performance regulators","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"rgt-mt18-reaktiivvoimsuse-kontroller-18-taseme-tcr-koos-rs485-modbusiga","title":"RGT-MT18 - Reactive power controller 18 levels +TCR with RS485 ModBus","description":"\u003cp\u003e \u003cstrong\u003e18 steps + TCR power factor controller for symmetrical\/asymmetrical networks with 5-inch touchscreen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e \u003cp\u003eReactive power control relays are designed to reduce the reactive power (inductive and capacitive) that is not used by the load and is taken from the network. When inductive power is taken from the network, it intervenes by removing a capacitor with an appropriate value. When capacitive power is taken from the power network, it intervenes by taking a shunt inductor with an appropriate value. In this way, it tries to reduce the inductive\/active and capacitive\/active speed of the system. Its purpose is to provide a more reasonable compensation in unbalanced inductive and capacitive systems with the RGT-MT18 TCR stage\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Voltage, harmonic current\/voltage, inductive and capacitive alarm output\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Hit, discharge and settling times are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Remote communication via RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Single, two and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be monitored up to the 61st harmonic.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cp\u003eTotal energy (import\/export) is traceable\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be monitored.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Power analysis (20 samples 9999 min.) - for capacitor selection.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Temperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Demand recording (active and reactive power and apparent power and current demand)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Minimum, maximum and average current and voltage values for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Actual date and time \u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071383728395,"sku":"RGT-MT18","price":334.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/29021cc84c53911daf6559abe27a8950.png?v=1755001978"},{"product_id":"rgt-12e-12-tasemeline-reaktiivvoimsuse-regulaator-tcr","title":"RGT-12E - 12-level reactive power regulator +TCR","description":"\u003cp\u003e \u003cstrong\u003e12 steps + TCR power factor controller with 2.9 inch graphic LCD display (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eThe RGT-12E\u003c\/strong\u003e reactive power regulator \u003cstrong\u003e(TENSE\u003c\/strong\u003e ) is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Digital processing of the values measured by the regulator ensures high accuracy in estimating effective voltage, current and power factor.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e \u003cp\u003eThe installation of the device is fully automatic - the controller itself determines the size of the individual connected compensation stages. These parameters can also be entered directly manually.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The controller switches the compensation stages on and off so that the reactive power is regulated with a minimum number of switching operations. At the same time, the controller takes into account the uniform load of the individual stages and preferentially switches off those stages that have been de-energized for the longest time and have the minimum residual charge. During the regulation process, the compensation stages are continuously monitored in parallel - faults and changes in values are detected, temporarily removed stages are periodically tested and, if necessary, they are re-included in the regulation process.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Hit, discharge and settling times are configurable\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Single, two and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be monitored up to the 31st harmonic value.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cp\u003eTotal energy can be monitored (import\/export).\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be monitored.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Power analysis (20 samples 9999 min.) - for capacitor selection.\u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071383826699,"sku":"RGT-12E","price":220.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/a1a8c8ce294759ea0cac4554bed17012.png?v=1755001982"},{"product_id":"rgt-12svc-reaktiivvoimsuse-kontroller-12-tasemeline-tcr-koos-rs485-modbus-rtu-ga","title":"RGT-12SVC - Reactive power controller 12-level +TCR with RS485 ModBus RTU","description":"\u003cp\u003e \u003cstrong\u003e12 steps + TCR power factor controller with 2.9\" graphic LCD display and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eThe RGT-12SVC\u003c\/strong\u003e reactive power regulator \u003cstrong\u003e(TENSE\u003c\/strong\u003e ) is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Digital processing of the values measured by the regulator ensures high accuracy in estimating effective voltage, current and power factor.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The installation of the device is fully automatic - the controller itself determines the size of the individual connected compensation stages. These parameters can also be entered directly manually.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e \u003cp\u003eThe controller switches the compensation stages on and off so that the reactive power is regulated with a minimum number of switching operations. At the same time, the controller takes into account the uniform load of the individual stages and preferentially switches off those stages that have been de-energized for the longest time and have the minimum residual charge. During the regulation process, the compensation stages are continuously monitored in parallel - faults and changes in values are detected, temporarily removed stages are periodically tested and, if necessary, they are re-included in the regulation process.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Hit, discharge and settling times are configurable\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Remote communication via RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Single, two and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be monitored up to the 31st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e All energy (import\/export) can be monitored.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be monitored.\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cp\u003ePower analysis (20 samples 9999 min.) - for capacitor selection.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071383990539,"sku":"RGT-12(SVC)","price":262.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/ae4bcd478955332c8f4396aa87708907.png?v=1755001987"},{"product_id":"12-tasemeline-reaktiivvoimsuse-kontroller-led-ekraaniga","title":"12-level reactive power controller with LED display","description":"\u003cp\u003e\u003cstrong\u003e12-step Single-Phase Power Factor Controller for Power Factor Control in Networks with Symmetrical Loads (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe RGM-12S reactive power control relay is designed to reduce inductive power that does not use loads but is drawn from the grid. When inductive reactive power is drawn from the grid, it intervenes by activating capacitors of appropriate value. In this way, it attempts to bring the Cos phi value to the desired level.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e7 Different power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eManual power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCan only compensate inductive systems\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic step measurement\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStep engagement, disengagement, and discharge are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable voltage and current harmonic distortion values\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOver- and under-compensation alarm values can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic voltage\/current, over- and under-compensation alarm outputs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, current, and frequency values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActive power, reactive power, and apparent power values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-I can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-V can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCosine value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower factor value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic fan output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEqual aging in steps (in some compensation programs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071384056075,"sku":"RGM-12S","price":168.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/0764c9ac7c5fc216c12aa893b22e4e13.webp?v=1755001990"}],"url":"https:\/\/pelek-ee.com\/en\/collections\/joudluse-regulaatorid.oembed","provider":"PELEK_EE","version":"1.0","type":"link"}