{"title":"The Chronicles","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"elektrooniline-impulsside-loendur-impulsside-loendur","title":"Electronic pulse counter \/ pulse counter + -","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral specifications for DS-72A pulse counter:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x 6-digit display,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x PRESET value,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x OUT output relay,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x SSout for SSR relay control.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounts signals from mechanical switches, limit switches, PNP\/NPN inductive proximity sensors, and incremental encoder inputs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUp\/down counting.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePassword protection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelectable input frequency: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCalibration constant: 0.00001.....9.99999.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelectable decimal point: 0 \/ 0.0 \/ 0.00 \/ 0.000.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFunction combination options: 7 input functions \/ 10 output functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAddition,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003esubtraction,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eadding\/subtracting from two inputs simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ecounting\/decreasing pause controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003einput negation controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eadding\/subtracting according to the leading edge \/ falling edge \/ both edges simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eadding by the leading edge \/ subtracting by the falling edge \/ function negation by the second input.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable \"OFFSET\" for calculated value.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePRESET1 with absolute\/relative value selection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT 2x relay: ON when value is reached and held until RESET or pulse between 0.1.....999.9 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRemembers the pulse count value and OUT relay status during the last power outage and can be reset when power is reconnected.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRESET via front panel pushbutton or signal to terminal RESET(17).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCan display preset ½ values.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEEPROM memory for saving settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical specifications:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions \/ \u003c\/span\u003e\u003cspan lang=\"CS\"\u003eopening : 72x72x94 mm \/ 67x67 mm.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay : 2x 6-digit 7-segment LED display.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndicator LEDs: 5x: OUT1, OUT2, Finger1, Finger2, Batch.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInputs: 2x (Max: 7500 Hz, 5-30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNPN selection: connect terminal \"npn select\" (13) to terminal \"+12V\" (14) to connect an NPN sensor connected to inputs Cp1 (15) and Cp2 (16).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe reset input is always PNP.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor a totem pole encoder or a PNP type encoder, \"npn select\" is not connected.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput types: mechanical switch, inductive encoder PNP\/NPN encoder output NPN\/PNP\/totem pole.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput frequencies: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset signal: RESET terminal (17), at least 10 ms, + signal (PNP only) (5...30 V).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutputs (OUT):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x SPDT relay 250 VAC, 2A, resistive load,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT1: terminals 6=COM, 5=NO, 7=NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT2: terminals 9=COM, 8=NO, 10=NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSSout 2x SSR control - NPN, 30V, 100mA max, terminals 18=SSout1, 19=SSout2, 20=GND\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSensor power supply: terminal (14) 12 VDC, 50 mA (max.), unregulated.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower voltage: 100...240 VAC, 50-60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower consumption: \u0026lt; 8 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature: -20°C ... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAltitude: \u0026lt;2000m\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation notes:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse shielded and twisted signal cables and connect the shield to ground. Keep all signal cables away from circuit breakers, inductive loads, devices\/cables that generate electrical noise, and power cables. Take precautions against environmental factors such as humidity, vibration, pollution, and high\/low installation temperatures.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse fuse protection (F250mA 250VAC) on the device's mains\/power input.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse suitable cables for the power supply. Follow safety instructions during installation.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor encoders, prefer to use the (Inpt = Phs1) option,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelect (Freq = 20) for counting pulses from a mechanical ON-OFF switch.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAlways select the minimum input frequency option that suits your application.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf Inpt = 1u2u, 1u2d, Phs2; the input signal frequency must not be greater than ½ of the selected input frequency option if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eIf Inpt = Phs4; the input signal frequency must not be greater than 1\/4 of the selected input frequency option if both inputs are used.\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071237878027,"sku":"DS-72A","price":75.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/ab941bd3c6a16fc1cbd1cc9b9dc9eb5a.png?v=1754998228"},{"product_id":"elektrooniline-impulsside-loendur-impulsside-loendur-1","title":"Electronic pulse counter \/ pulse counter","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePulse counter for DS-48 panel\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(2x 4-digit display: 1x counter, 1x target value)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral specifications of the DS-48 pulse counter:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x 4-digit display, 1x preset value,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x OUTput relay,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ecount\/down counter\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounts signals from mechanical switches, inductive PNP\/NPN proximity sensors, and incremental encoder inputs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePassword protection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelectable input frequency: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCalibration constant: 0.001.....9.999\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelectable decimal point: 0, 0.0, 0.00, 0.000\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e7 input functions \/ 9 output functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Counting,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- counting,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- adding\/counting from two inputs simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- counting\/counting pause controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- input negation controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- adding\/subtracting from rising edge \/ falling edge \/ both edges simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- adding on rising edge \/ subtracting on falling edge \/ negating function by second input\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable \"OFFSET\" for the calculated value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutput relay: switches on when the value is reached and holds until RESET or a pulse in the range of 0.1.....999.9 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMemorizes the pulse count value and the status of the OUTput relay during the last power outage and can be reset after the first power-up.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset by front panel button or signal on RESET terminal (12).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEEPROM memory for saving settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation notes:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse shielded and twisted signal cable and ground the shield. Keep all signal cables away from circuit breakers, inductive loads, electrical noise generating devices\/cables, and power lines.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAvoid environmental influences such as moisture, vibration, dirt, and high\/low temperatures.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse circuit protection (F250mA 250VAC) on the device's mains\/power input.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse appropriate cable for the power supply. Observe safety regulations during installation.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore the encoder, preferably use (Inpt = Phs1), select (Frequency = 20) for counting pulses from a mechanical ON-OFF switch,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eselect the optimal minimum input frequency suitable for your application.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor Inpt = 1u2u, 1u2d, Phs2; the input signal frequency must not be higher than ½ of the selected input frequency when both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor Inpt = Phs4; the input signal frequency must not be higher than 1\/4 of the selected input frequency when both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical parameters:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions \/ \u003c\/span\u003e\u003cspan lang=\"CS\"\u003eopening: 48x48x96 mm \/ 44x44 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay: 2x4-digit 7-segment LED display.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNumber of inputs: 2 x (Max: 7500 Hz, 5-30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput type: mechanical switch, inductive sensor PNP\/NPN, encoder output NPN\/PNP\/totem pole\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput frequencies: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNPN sensor selection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset input is always PNP.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e\"npn select\" is not connected before totem or PNP sensors.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset signal: terminal (12), at least 10 ms, + signal (PNP only) (5.....30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply voltage: 100...240 V AC, 50-60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower consumption: \u0026lt; 8 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutput (OUT):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x SPDT relay 250 VAC, 2A, resistive load, terminals 4=COM, 3=NO, 5=NC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x SSR control - NPN, 30V, max 100mA, terminal 13=SSout, 14=GND.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSensor supply: terminal (9) 12 VDC, 50 mA (max.), unregulated.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature: -20°C ... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eAltitude of use: \u0026lt;2000m\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071238402315,"sku":"DS-48","price":51.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/cfb2f9676258fd2afc433ada5d9eb246.png?v=1754998237"}],"url":"https:\/\/pelek-ee.com\/en\/collections\/loendurid.oembed","provider":"PELEK_EE","version":"1.0","type":"link"}