{"title":"Level regulators","description":"\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e \u003cmeta charset=\"utf-8\"\u003eAt Pelek-ee.com, we offer reliable and accurate level controllers from Turkish manufacturers. These controllers are essential for maintaining the correct level of liquids in your industrial processes, which is crucial for their efficient and safe operation. Our level controllers are designed for high reliability, longevity and easy installation. Thanks to our own warehouses in the Czech Republic, we can ensure fast delivery and professional support in selecting and installing the right equipment according to your needs.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"regulaator-uhefaasilise-pumba-jaoks-kuni-30a","title":"Regulator for single-phase pump up to 30A","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSingle-phase submersible pump controller, 140 V-280 V AC, 60 A, Tense\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eArt.nr: MDK-02\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes (liquid level sensors) are not included.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis controller is designed to protect submersible borehole pumps from a variety of potential problems that can arise during operation, such as voltage and current fluctuations, water shortages in the borehole or well, and pump overload. Built-in functions also allow monitoring the reservoir fill level, setting time delays for emergencies, and adjusting surge currents.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eController operation principle.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore connecting the device, please read the \"Important!\" section. Connect the sensors and current transformer to the device according to the wiring diagram (Figure 1), and then connect to the mains. Check that the factory-set parameters match your pump's operating parameters. If necessary, the following parameters can be changed:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P1) - maximum allowed voltage value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P2) - maximum allowed current value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P3) - minimum allowed voltage value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P4) - minimum allowed current value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P5) - fault response delay\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P6) - auto-reset time after current failure\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P7) - current coefficient (multiplier) for the startup interval.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P8) - startup interval time\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P9) - number of current fault auto-resets, after which the device enters emergency mode and requires operator intervention.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P10) - upper sensor response delay time (longer time - pump switches on fewer times - extends pump life)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter the first connection to the mains, the device waits for 4 seconds, then analyzes network parameters and their compliance with the set parameters, and checks for water in the well. It verifies if there is enough space in the well reservoir, and if the controller is in \"START\" mode (bottom green indicator illuminated), the control contacts switch on and the upper green \"pump\" indicator illuminates. The display shows current voltage and current values.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePress START to enter this mode.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePress STOP to enter this mode. In this mode, the device performs no regulation and does not start the pump.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eParameter settings:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePress the MENU button to enter the parameter settings menu. You will land on the first parameter page (P1). The upper display shows the parameter number, and the lower display shows the value of that parameter. You can change the parameter values by pressing the UP and DOWN buttons. Then, press the MENU button to save the selected value, or the RESET button to exit the menu. Note that pressing the RESET button will not save the parameter value displayed on the screen, but changes to previous parameters will be saved. If no button is pressed for 50 seconds, the device will exit the menu without saving the parameter value displayed on the screen.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eImportant!!! Read this section before connecting the device:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- The submersible pump control unit must be connected according to the wiring diagram in the product datasheet.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Ensure that the liquid being pumped by the pump is not flammable or explosive.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- If a system with two level sensors is used, the inputs for the upper and middle sensors must be connected.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- The temperature at the controller installation location must be above 0 °C.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Never apply voltage to the controller inputs to connect a float switch.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Ensure that the pump casing is grounded, otherwise the pump controller may be damaged.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical information:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating voltage: 140-280 VAC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFrequency: 50 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCurrent range: 0.5-60 A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower consumption: \u0026lt;4 W\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSensitivity to liquids: \u0026lt;50 kOhm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection class: IP40\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature range: -5 °C- +55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCable cross-section: max. 1.5 mm2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight: 0.325 kg\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMounting hole: 91 x 91\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eInstallation height: below 2000 m\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071566967051,"sku":"MDK-02","price":84.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/7e59b54c85045a578e7f7c49529b5d8b.png?v=1755005279"},{"product_id":"puurkaevu-tasememootja-regulaator-uhefaasilise-pumba-jaoks-din-30a","title":"Borehole level meter \/ Regulator for single-phase pump DIN 30A","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eControl unit for single-phase submersible pump up to 4 kW, 150 V-270 V AC, 30 A, Tense\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eArt.nr: MDK-03\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes (liquid level sensors) are not included\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTense's new MDK-03 control unit is designed to protect single-phase submersible pumps from all possible problems that may arise during operation, including overvoltage and undervoltage, lack of water in the well or borehole, and pump overload. The built-in functions also allow monitoring the filling level of the reservoir, setting time delays for emergencies, monitoring overcurrents, and remotely switching the system on and off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical information:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating voltage: 150-270 VAC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFrequency: 50 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCurrent range: 1-30 A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower consumption: \u0026lt;6 W\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLiquid sensitivity: \u0026lt;50 kOhm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection class: IP20\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature range: -20 °C to +55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCable cross-section: 10 mm², electrodes up to 2.5 mm².\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight: 0.25 kg\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation altitude: below 2000 m\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eController operation principle\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore connecting the device, please read the \"Important!\" section. Connect the sensors and the pump phase wire to the device according to the wiring diagram provided in the datasheet, and then connect the power supply. Check that the factory settings of the device match your pump's operating parameters. If necessary, the following parameters can be changed:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P1) - Maximum permissible voltage (230...270 V, factory setting 245 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P2) - Maximum permissible current (1...20 A, factory setting 5 A)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P3) - Minimum permissible voltage (150...210 V, factory setting 160 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P4) - Minimum permissible current (1...20 A, factory setting 0 A)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P5) - Fault response delay (0...850 s, factory setting 2 s)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P6) - Automatic reset time after current fault (OFF...850 s, factory setting OFF)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P7) - Start-up interval current multiplier (1...10, factory setting 3) (P8) - Start-up interval time (0...850 s, factory setting 10 s)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P9) - Number of automatic current fault resets, after which the device goes into emergency mode and requires operator intervention (OFF....200, factory setting OFF).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P10) - Upper sensor response delay time (longer delay means the pump switches on fewer times, extending its lifespan) (0....850 min, factory setting 0 s min)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P11) - Indicates whether the electrodes are in water: if the value is less than 230, there is water (red indicator shows the upper electrode, yellow indicator shows the lower electrode).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(P12) - Programs the last state of the controller before shutdown into memory (0...1, factory setting 1)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter connecting to the power supply for the first time, the device waits for 4 seconds, then analyzes the network parameters and their correspondence to the set parameters, checks if there is water in the well, if there is space in the tank, and if the controller is in \"START\" mode (green \"START\" indicator is on), it switches on the control contacts and the upper green \"pump\" indicator lights up. The indicators show the current voltage and current values.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTo enter this mode, press the START button.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTo enter this mode, press the STOP button. In this mode, the device does not perform any adjustments and does not start the pump.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePlease also note that if you intend to use the level relay without a float sensor and remote switch, be sure to place jumpers on the \"ON-OFF\" and \"FLATOR\" terminals; otherwise, the controller will not work or will not work correctly.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eImportant!!! Read this section before connecting the device:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- The submersible pump controller must be connected according to the wiring diagram in the product datasheet.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Make sure that the liquid pumped by the pump is not flammable or explosive.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- The temperature at the controller installation site must be above 0 °C.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- Never apply voltage to the controller inputs to connect a float sensor.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003e- Ensure that the pump casing is grounded, otherwise the pump controller may be damaged.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071568310539,"sku":"MDK-03","price":98.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/0809d8808eeba3d0681be7f1cdf23ddf.png?v=1755005288"},{"product_id":"ujuvtaseme-luliti-puhtale-veele-taitmine-tuhjendamine-no-nc-pvc","title":"Float level switch for clean water (filling, draining), NO+NC, PVC","description":"\u003cp\u003eLevel switches are mechanical control devices that provide an electrical contact in response to the rise and fall of a certain amount of water, such as a tank or well. They are designed to ensure that the water level is constantly maintained within a certain range or to turn other devices on and off according to the water level.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"1.6m","offer_id":52071569326347,"sku":"FLT-1.6","price":10.92,"currency_code":"EUR","in_stock":true},{"title":"3m","offer_id":52071569359115,"sku":"FLT-3","price":12.4,"currency_code":"EUR","in_stock":true},{"title":"5m","offer_id":52071569391883,"sku":"FLT-5","price":11.96,"currency_code":"EUR","in_stock":true},{"title":"10 m","offer_id":52071569424651,"sku":"FLT-10","price":21.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/file_b9736666-0279-4b07-96a5-636812fec033.webp?v=1755005298"},{"product_id":"pumba-kaitse-kuivkaigu-eest-din-sukelpumpade-kontroller","title":"Pump dry-running protection, DIN submersible pump controller","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePump control units for submersible and borewell pumps, max current 30 A, 200 V-460 V AC, Tense\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes (liquid level sensors) not included\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePump control and emergency protection devices\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis device is designed to control submersible pumps and motors used in boreholes and other containers, and to protect them from adverse conditions such as dry running, overvoltage, and current or voltage imbalance.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMain features\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCurrent range: 1 A-30 A.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBuilt-in components: current transformers and contactor.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOvervoltage\/undervoltage.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOvercurrent\/undercurrent.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCurrent\/voltage imbalance.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOther functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSetting of fault times.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAutomatic reset of timer and counter.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSupports manual, semi-automatic and automatic reset modes.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eShutdown time multiplier and time setting.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePhase sequence check.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay of the number of contacts used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMonitoring of total operating time.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLiquid level sensors: not included, must be ordered separately.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWater level sensors and float sensor must be ordered.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical data:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating voltage (Un): 100-240 VAC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOverload current: up to 30 A.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay: 3-digit LED display with 8 indicators.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLiquid sensitivity: \u0026lt;50 kOhm.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating power: \u0026lt;10 VA.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature: -20 °C to +55 °C.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCable diameter: up to 2.5 mm² and 6 mm² for current inputs and outputs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eContacts: 3 A \/ 250 V AC (resistive load).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating altitude: up to 2000 m.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMounting: DIN rail.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice weight: up to 380 g.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eApplication:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos minor-latin new=\"\" roman mso-ascii-theme-font:minor-latin=\"\" mso-bidi-theme-font:minor-bidi=\"\" mso-bidi-language:ar-sa=\"\"\u003eThis device is ideal for protecting pumps from dry running, preventing overload, and controlling equipment in various industrial and domestic applications.\u003c\/span\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071569621259,"sku":"TDK-30","price":105.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/395faea6dc3a503f2c31184a1d540344.png?v=1755005300"},{"product_id":"sukelpumba-juhtimisrelee-puurkaevu-mahuti-taseme-indikaator","title":"Submersible pump control relay, well tank level indicator","description":"\u003cp\u003e\u003cstrong\u003eProtection Relay - submersible pump control device, pump protection, pump control relay, borewell level meter, borehole level meter, tank level meter, TDK-01, TDK-02 (TENSE) \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003e1A - 120A (TDK-01) \/ 2A - 300A (TDK-02) submersible pump.\u003c\/li\u003e\t\u003cli\u003ePump protection against dry running\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eAbility to work without probes\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eHigh and low level set\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eHigh\/low voltage protection\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eHigh\/low current protection\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eProtection against voltage asymmetry\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eRetains error logs\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eStar-delta contact output\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003e2 adjustable alarm outputs\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eMeasuring transformer included\u003c\/p\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"120A","offer_id":52071569785099,"sku":"TDK-01","price":168.0,"currency_code":"EUR","in_stock":true},{"title":"300A","offer_id":52071569850635,"sku":"TDK-02","price":189.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/file_2b0c13b6-5de0-4bf6-898d-98a69b3cedfb.png?v=1755005307"},{"product_id":"vedelikutaseme-relee-aurukatelde-jaoks-kaev-voi-paak","title":"Liquid level relay for steam boilers (well or tank)","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eA relay is installed for regulating the water level in two condensate water heating systems (steam generators), which switches off the electric heater if there is no water in the tank.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrical circuit diagram of the water level control relay in the heater\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMake the wiring according to the diagram\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCom Elect. - common electrode (not included).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTank Elect - electrode for checking the water level in the well (not included).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBoiler Elect - electrode for checking the liquid level in the boiler - tank (not included).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRes Elect - electrode for checking the liquid level for switching on the liquid heater (not included).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRes. Out - output for connecting the liquid heater.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWater Not - output for connecting a signal lamp (heater on\/off)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect (Com Elect) to the casing of the TANK well and to the boiler (tank, container) - BOILER. If the tank is not connected, connect (Com Elect) to the liquid level control electrode.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe water level in the tank (TANK) drops - until the water level is not lower than the liquid level sensor (Tank Elect), the pump turns on and the green \"motor running\" indicator lights up. If the water level drops below this sensor (Tank Elect), the motor stops and the \"motor running\" indicator turns off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe water level in the boiler, tank, vessel (Boiler Elect) rises - when the tank is filled up to the level electrode (Boiler Elect), the pump turns off (the green \"Pump running\" indicator stops glowing) and stops pumping water.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe water level in the boiler (tank, vessel) decreases - when the water level drops below the liquid level sensor (Boiler Elect), a 10-second pump start delay is activated. After the set time has elapsed, the pump motor starts (the \"motor running\" indicator lights up), pumping water up to the sensor level (Boiler Elect).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eA level electrode is also installed in the boiler to control the electric heating of the liquid (Res Elect). When the water rises to the sensor level (Res Elect), the indicator light goes out and the water heater turns on. If the water drops below the sensor level (Res Elect), the heater turns off and the indicator light turns on. Using an electrode to measure the water level in the heater prevents electric heating from turning on in the tank-boiler when there is no water, and the indicator light helps you know if the heater is working. The indicator light can serve as a water level indicator (below-above Res Elect electrode). This option prevents heater failure (operating without liquid - idle) and saves money.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes (liquid level sensors) are not included.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePlease be sure to order water level sensors and a 2 amp circuit breaker to protect the input and output channels of this device (3 pcs).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated voltage: 220 V, AC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating voltage range: 90% to 110%.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLosses: \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAmbient temperature: -40...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSensor and power connection: screw connection\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eInstallation: DIN rail or mounting panel\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071569948939,"sku":"SSR-19","price":16.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/1f260439db01cbf624587c651e27f3cf.png?v=1755005309"},{"product_id":"vedeliku-taseme-relee-aurukatelde-jaoks","title":"Liquid level relay for steam boilers","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBoiler water level control relay for installation in water heating systems, allowing the electric heater to be switched off in case of water shortage, for single-tank systems. SSR-09 TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe SSR-09 is an advanced boiler water level control relay designed for automatic water supply regulation and protection of the heater from dry operation. The device monitors the presence of liquid in the tank and automatically switches the pump and heater on or off depending on the water level.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMain advantages\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBoiler and heater dry-running protection extends equipment life.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAutomatic water level control: the relay switches on the pump when the water level is low and switches it off when the upper limit is reached.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eStatus indicators: built-in LEDs show the operation of the pump and heater.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEasy installation: DIN rail mounting, convenient terminal connections.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCompact size and energy efficiency.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWide voltage range (170-260 VAC): stable operation even in case of overvoltage.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating principle\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe SSR-09 relay uses electrodes to detect water level:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWhen the water level drops below the set mark, the device switches on the pump to fill the tank.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWhen the water level reaches the upper limit, the pump automatically switches off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf there is no water near the heater, the relay blocks the power supply to the heater to prevent it from overheating.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis logic ensures that the boiler always operates safely and economically.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUsage\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectric boilers and thermal storage units\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHeating systems with a tank\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWater supply stations and pumping stations\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDrinking or domestic water and service water tanks and storage tanks\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation and connection\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation is done on a standard DIN rail in a cabinet.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection is made via screw terminals. Electrodes are installed in the tank at the required level (upper and lower regulation).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eTo ensure stable operation, it is recommended to use copper conductors with a cross-section of at least 2.5 mm².\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071570178315,"sku":"SSR-09","price":15.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/331942fa669f949c300016097ee9dafe.png?v=1755005313"},{"product_id":"tasemekontrolleri-puuraugu-tasememootja-koos-taseme-luliti-ajamiga-ssr-05d-tense","title":"Level controller, borehole level meter with level switch actuator SSR-05D TENSE","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWater level regulation in a well, borehole, tank, expansion tank. Three or two level sensors can be used for pumping or draining water from the tank. Sensor sensitivity adjustment + response delay time adjustment. SSR-05D, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis water level relay has several important differences compared to other similar water level control relays presented on this website.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis relay is digital, which means it contains a microprocessor that controls the entire operation of the device. This allows for the implementation of additional functions that not only increase ease of use but also extend the lifespan of water level sensors.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1) The current between the water level sensors does not flow continuously, but in pulses – this extends the life of electrodes immersed in water by more than 2 times!\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2) The SSR-05D has a built-in pump delay time. This is a useful feature if the relay is used, for example, in a well (or wells) where the water level changes depending on the season – accordingly, there is no need to change the position of the upper sensor – it is sufficient to change the relay's delay time.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e3) This level relay is also equipped with 3 LEDs that indicate how the water has filled the tank – upper, middle, and lower levels. I agree that this is convenient if the relay is installed inside the house and the tank is on the roof, in the basement, or outdoors.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes (liquid level sensors) are not included.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePlease be sure to order water level sensors and a 2 amp circuit breaker to protect the input and output channels of this device (2 pcs).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated voltage: 220 V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating range: 150 V-260 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating power: \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection: with terminal block\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions (mm) 44x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight 250 g\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eConnection type: DIN rail + screws\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071570440459,"sku":"SSR-05D","price":34.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/e63495f2a01071dd517206ea47cb86ea.png?v=1755005321"},{"product_id":"tasemeluliti-taitetaseme-monitor-tuhjendusmootur-puurkaevule-vsr-05-tense","title":"Level switch \/ fill level monitor, discharge meter for borehole VSR-05 TENSE","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelays for water level control in tanks, wells, boreholes, expansion tanks. Control of water pumping or overflow, possibility of using three or two level sensors. Sensor sensitivity adjustment. VSR-05, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePlease do not forget to order water level sensors and a 2 amp circuit breaker to protect the input and output channels of this device (2 pcs).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated voltage: 220V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating range: 170V-260V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating power: \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection: clamp\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions (mm) 22.5x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eWeight 250 g.\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071570669835,"sku":"VSR-05","price":30.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/643f979a7a582e895ea3fd644677f054.png?v=1755005329"},{"product_id":"taitmise-taseme-kontroller-tuhjendusluliti-kaevu-tasememootja-ssr-05","title":"Filling level controller, drain switch well level gauge SSR-05","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eTENSE SSR-05 liquid level control relay for wells, tanks, reservoirs or boreholes.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eDomestic surface and submersible centrifugal water pumps are usually equipped with thermoplastic hydraulic components and cannot operate without water in \"dry friction\" conditions even for a short time.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eWater not only lubricates the friction surfaces but also acts as a coolant, absorbing and dissipating heat generated by friction. A centrifugal pump must be protected against possible dry running or lack of water. Potentially dangerous applications for centrifugal pumps due to the risk of dry running include pumping water from wells or boreholes where the flow rate is low or insufficient, pumping water from tanks or reservoirs with limited or replenishable volumes, and operating in pressure boosting systems. An intelligent pump without functional protection cannot independently detect a lack of water in the suction line or well and shut down.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eThe SSR-05 well, tank, reservoir, or borehole water level monitoring relay is a simple and reliable device for monitoring the water level in a well using two or three level sensors, with adjustable sensor sensitivity and an LED indicator for the well\/reservoir water level. The SSR-05 relay can also be used to control a pump for filling a tank or to indicate leaks and pump shutdowns.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eTherefore, it is preferred for protecting a pump that is at risk of running dry or running out of water in its suction line. The SSR-05 relay for checking the liquid level in a well, tank, reservoir, or borehole is one of the devices that can reliably eliminate the potential risk of a pump running dry.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eRated voltage: 220 V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating range: 170 V-260 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating power: \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eConnection: with terminal\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eDimensions (mm) 44x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size: 12pt; line-height: 115%; font-family: Aptos, sans-serif; font-weight: normal;\"\u003eWeight: 250 g.\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071571423499,"sku":"SSR-05","price":30.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/54bb5063b5b0d4e8d358a0545361a8ea.png?v=1755005349"},{"product_id":"sse-10-tense-veetaseme-regulaatorile-moeldud-roostevabast-terasest-tasemeandur-pvc-korpuses","title":"Stainless steel level sensor in PVC housing for SSE-10 TENSE water level controller","description":"\u003cp\u003e \u003cstrong\u003eStainless steel level sensor with PVC coating for SSE-10 TENSE water level controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e A very practical solution for water tanks (metal and plastic) - long life guarantee, convenient use, quick replacement if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e A detection probe is an electrode that, together with a suitable evaluation device, is used to detect levels, e.g. in wells, boreholes, tanks...\u003c\/li\u003e\n\n\u003cli\u003e intended for use in electrically conductive and mechanically contaminated liquids in the temperature range +1... +90 °C.\u003c\/li\u003e\n\n\u003cli\u003e suitable for use in drinking water\u003c\/li\u003e\n\n \u003cli\u003estainless steel single-pole electrode housed in a PVC housing designed to be hung on the tank wall or attached via a sleeve.\u003c\/li\u003e\n\n\u003cli\u003e For the probe to function properly, it is necessary to ensure that the probe electrode is clean and free of any impurities that could prevent the electrode from contacting the liquid. If the electrode is clogged, the probe may malfunction.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Screw thread connection, up to 2.5 mm2.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071572635915,"sku":"SSE-10","price":4.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/efc7b17974b7edcc2ff6e79567a46250.png?v=1755005377"},{"product_id":"hudrofooride-jarjestusreziimi-relee-koos-taimeriga","title":"Hydrophore sequence mode relay with timer","description":"\u003cp\u003e\u003cstrong\u003eHydrophore sequential relay with timer for 2 pumps\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eHydrophore sequential relays are designed to control the number of pressure-controlled pumping stations and to ensure that the pumping stations operate simultaneously.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071573192971,"sku":"HSR-02X","price":55.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/d059fb446486058e2c0ef96b20274041.png?v=1755005395"},{"product_id":"hudrofooride-jarjestuse-relee","title":"Hydrophore sequence relay","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral Information\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe hydrofoil shear relays are designed to\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003estart and operate simultaneously when required.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice Usage and Principle of Operation\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe sequence of hydrofoils is as follows: (H1) - (H2) - (H3) and (H1-H2) -.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(H2-H3) - (H1-H3). This activates the hydrofoils at the same number,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ewhere the switches are closed and keeps them operating for a time period \"t\". At the end of time \"t\", the next hydrofoil or group of hydrofoils is activated and\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eit continues in this manner. It deactivates the hydrophones at the same number,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ewhere the switches are open.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNote: Do not connect current to the inputs and outputs (P1, P2, P3).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003epressure switch.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMaintenance\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTurn off and unplug the device. Clean the device's cone with a swab. Do not use wires or chemicals that could\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003edamage the device. After cleaning, ensure the device is working.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWarning\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse the device according to the instruction manual.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDo not use the device in a humid environment.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThe device contains a switch and a circuit breaker.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePlace the switch and circuit breaker near the device so that the operator can easily access them.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMark the switch and circuit breaker as follows\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003edevice release connection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical Specifications:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating Voltage (Un).....: 150-250V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating Frequency.......: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating Power..............: \u0026lt;6VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating Temperature....: -20°C.... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTime(t)......................: 10 minutes\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay......................: HSR-02=5 x LED, HSR-03=7 x LED\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection Type............: Terminal connection\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eContact.....................: 3A\/250V AC (resistive load)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNumber of Hydrophones........: 2 (HSR-02) and 3 (HSR-03).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCable Diameter..............: 1.5 mm² (HSR-02), 2.5 mm² (HSR-03)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight..........................: max. 220g.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation..........................: Vertical panel or DIN rail mounting.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eOperating Altitude............: \u0026lt;2000 meters\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52071591575819,"sku":"HSR-22","price":53.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/files\/aa88925fd727fe8fc49216594593de82.jpg?v=1755005564"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0930\/5463\/2203\/collections\/de43e40e9855d727e5ad2daabb48f03a.webp?v=1748242273","url":"https:\/\/pelek-ee.com\/en\/collections\/taseme-regulaatorid.oembed?page=2","provider":"PELEK_EE","version":"1.0","type":"link"}