3-phase network parameter analyzer
Failed to load pickup availability
Online payment by card - after completing your order, you will be redirected to the payment gateway, payment confirmation will be sent to you by email
Arrival - payment according to the payment order, you pay the driver of the transport company
By transfer - a prepayment invoice will be sent to your email address no later than the next business day, with the bank account number that you enter when making the payment.
By invoice - this payment option is used by partners who have a framework agreement with our company.
If you want to use the last 2 methods, call our manager and he will give you instructions on how to receive an invoice with or without VAT.
The electrical appliances we offer meet high quality standards, have a 24-month warranty, and meet all EU requirements.
In the case of advertising, no fees are charged for returning the goods.
3-phase network analyzer / network analyzer / network parameter meter - multifunctional digital panel meter, current, voltage, frequency and total power indicator, with two relay outputs and digital inputs, RS485 ModBus RTU - TPM-01ESH manufacturer TENSE (Turkey)
Multifunctional power network analyzer is designed for accurate measurement of three-phase network parameters
Power analyzers are designed to measure and monitor electrical values. The communication function allows energy measurements to be monitored and reported independently.
Main advantages:
- RS485 Modbus RTU (1200-38400bps).
- 3-phase voltage transformer and 3-phase current transformer.
Displays voltage and current harmonics up to the 31st harmonic
Shows active power per phase (P)
Shows reactive power per phase (Q, inductive and capacitive).
Shows apparent powers in phase (S)
Shows Cosφ and power factor values for each phase
-
Displays the voltage (V) and current (I) values between each phase and neutral, measuring the frequency.
Shows the total values of imported and exported active energy (ΣkWh).
Shows the total values of inductive and capacitive reactive energy (ΣkVArh).
Shows minimum and maximum values, maximum need
2 relay outputs, 1 digital input
Event logs (high/low voltage/current, voltage/current imbalance, THD-I)
The menu is password protected.
Typically, this network analyzer is used with current measuring transformers - 60/5 75/5 100/5 150/5 200/5 250/5 300/5 400/5 500/5 600/5 800/5 1000/5 1500/5 etc. You can purchase such transformers from our online store. If you plan to connect the analyzer to ModBus, we can send you a register table with ModBus addresses upon request.