Three-phase current relay for load current control/limitation in the range of 190-300 A, manufacturer TENSE (Turkey)
Digital overcurrent relays TRM-300 are designed to protect loads from damage caused by high currents while allowing operation monitoring.
- 190-300 A (adjustable overcurrent value) - 50% fixed current asymmetry - Adjustable fault delay time - Adjustable operating mode (automatic, semi-automatic, manual) - When purchasing a TENSE brand current relay, you receive a ready-to-use device - including current transformers.
Device usage and operating principle
- Connect the device according to the electrical diagram.
- When the wiring is ready, connect the device to the power supply. After switching on, the set values are displayed on the screen for 5 seconds.
- Use the "A>" regulator to set the overcurrent value. The set value is displayed on the left screen.
- Use the "t" regulator to set the delay time. The set value is also displayed on the left screen.
When the device is switched on: - The relay switches on, the output contact switches to terminal 3, and the OUT indicator lights up. - When the current exceeds the set overcurrent value (A>), the device starts counting the delay time and the ERR indicator lights up. - When the time has elapsed, the relay switches off, the contact switches to terminal 1, and the OUT indicator goes off.
The TRM-300 series electronic current relay is designed for automatic shutdown of devices when the maximum allowable current is exceeded. It has a programmable switching range, the ability to set switching time and return time. There are 3 programs to return to "Operating mode" - MANUAL, SEMI-AUTOMATIC, AUTOMATIC.
Return modes:
- Manual mode: After an overcurrent trip, the device must be reset by pressing the Reset button. The corresponding LED lights up in this mode.
- Semi-automatic mode: The system resets automatically three times after an overcurrent fault, then waits for manual reset on the next fault. The LED indicator is lit in this mode.
- Automatic mode: The system resets automatically after each overcurrent fault. The LED indicator is lit in this mode.
Note: To change the mode, hold the SELECT button for 10 seconds. The corresponding LED lights up when the mode changes.
Asymmetry 50% (fixed)
If the difference between the highest and lowest phase current exceeds 50%, the device enters asymmetry fault mode within 2 seconds.
(This prevents system damage in case of a single phase failure during motor operation).
During asymmetry fault:
- The indicator group of the two faulted phases flashes and the ERR indicator lights up.
- To exit asymmetry fault mode, the device must be reset manually.
Technical parameters:
- Operating voltage: 150-260 VAC.
- Operating frequency: 50/60 Hz
- Power consumption: < 6 VA
- Operating temperature: -20 °C to +55 °C
- Display: 3×3 digits, 5 LEDs
- Overcurrent setting (A>): 190-300 A
- Delay time: 1-200 s
- Connection type: clamp connection
- Contacts: 5 A / 250 V AC (active load)
- Wire diameter: 2.5 mm²
- Weight: max. 250 g
- Installation: DIN rail
- Operating altitude: < 2000 m
Note: Models TRM-50, TRM-100, TRM-200, and TRM-300 can only be used with the current transformers supplied with the device. Model TRM-400 can be used with a 400/5 current transformer.
Basic
|
Manufacturer
|
Tense
|
|
Country of manufacture
|
Turkey
|
|
Type of installation
|
Mountable on DIN rail
|
|
Number of auxiliary contacts
|
1 pc.
|
|
Number of switching contacts
|
1 pc.
|
|
Cross-section of connected wires
|
2.5 mm²
|
|
Housing material
|
Plastic
|
|
See
|
Yes
|
|
Weight
|
250 g
|
|
On/off LED
|
Yes
|
|
"Overload" LED
|
Yes
|
|
Minimum storage temperature
|
-25 degrees.
|
|
Maximum storage temperature
|
55 degrees.
|
|
Protection level IP
|
30
|
|
Lifetime
|
10 years
|
|
Technical data
|
|
|
Number of phases
|
3
|
|
Rated operating voltage
|
220V
|
|
Rated current
|
5A
|
|
Frequency
|
50 Hz
|
|
Rated current
|
3W
|
|
Minimum operating temperature
|
-25 degrees.
|
|
Maximum operating temperature
|
55 degrees.
|
|
Overall dimensions
|
|
|
Length
|
85 mm
|
|
Height
|
75 mm
|
|
Width
|
44 mm
|
|
User features
|
|
|
Delay time
|
1 s -200 (s)
|
|
Installation
|
DIN screws
|
|
Range
|
190-300A
|
|