Load monitoring/limiting relay, 3-phase, range 290-400 A, manufacturer TENSE (Turkey)
The TRM-400 digital overload relay is designed to protect loads from damage caused by high currents, while allowing operational control.
- 290-400 A (adjustable overload value)
- Adjustable fault delay time
- Adjustable operating mode (automatic, semi-automatic, manual)
- When purchasing a TENSE current relay, you get a ready-to-use device - current transformers are included.
Device operation and working principle
- Connect the device according to the attached wiring diagram.
- Once the wiring is complete, connect the power supply. After power-on, the set values will be displayed on the screen for 5 seconds.
- Use the "A>" regulator to set the overload value. The set value will be displayed on the left screen.
- Use the "t" regulator to set the delay time. The set value will also be displayed on the left screen.
When the device is switched on:
- The relay switches on, the output contact switches to terminal 3 and the OUT indicator lights up.
- If the current exceeds the set overload value (A>), the device counts down the delay time, after which the ERR indicator lights up.
- After the set time has elapsed, the relay switches off the contact, switches to terminal 1 and the OUT indicator goes out.
The TRM-400 series electronic current relay is designed for automatic disconnection of consumers when the maximum permissible current is exceeded. It has a programmable switching range and the ability to set the switching time and reset time. There are 3 modes for returning to "operating" state - MANUAL, SEMI-AUTO, AUTO.
Reset modes
- Manual mode: To reset the device after an overload, the Reset button must be pressed. In this mode, the corresponding LED lights up.
- Semi-automatic mode: Allows the device to automatically reset the system three times in case of overload and then waits for a manual reset on the next fault. The corresponding LED lights up.
- Automatic mode: The device allows the system to automatically reset every time an overload fault occurs. The corresponding LED lights up.
Note: To change the mode, hold down the SELECT button for 10 seconds. When the mode is changed, the corresponding LED lights up.
Technical parameters
- Operating voltage: 150-260 VAC
- Operating frequency: 50/60 Hz
- Power consumption: <6 VA
- Operating temperature: -20 °C ... +55 °C
- Display: 3 × 3 digits, 5 LEDs
- Overload value (A>): 290-400 A
- Delay time: 1-200 s
- Connection type: clamp connection
- Contacts: 5 A / 250 V AC (active load)
- Cable diameter: 2.5 mm²
- Weight: max. 250 g
- Installation: DIN rail
-
Maximum altitude: <2000 m
Note: TRM-50, TRM-100, TRM-200 and TRM-300 can only be used with the included current transformers.
The TRM-400 can be used with the 400/5 current transformer included with the TRM-400.
Basic
|
Manufacturer
|
Tense
|
|
Country of manufacture
|
Turkey
|
|
Mounting type
|
DIN rail mountable
|
|
Number of normally open contacts
|
1 pc.
|
|
Number of changeover contacts
|
1 pc.
|
|
Cross-section of connected conductors
|
2,5 mm²
|
|
Housing material
|
Plastic
|
|
View
|
Yes
|
|
Weight
|
250 g
|
|
On/off LED
|
Yes
|
|
"Overload" LED
|
Yes
|
|
Minimum storage temperature
|
-5 degrees.
|
|
Maximum storage temperature
|
55 degrees.
|
|
Protection level IP
|
30
|
|
Lifetime
|
10 years
|
|
Technical data
|
|
|
Number of phases
|
3
|
|
Rated operating voltage
|
220V
|
|
Rated current
|
5A
|
|
Current frequency
|
50 Hz
|
|
Rated power
|
3W
|
|
Minimum operating temperature
|
-5 degrees.
|
|
Maximum operating temperature
|
55 degrees.
|
|
Overall dimensions
|
|
|
Length
|
85 mm
|
|
Height
|
75 mm
|
|
Width
|
44 mm
|
|
User features
|
|
|
Delay time
|
1 s -200 (s)
|
|
Installation
|
DIN+screws
|
|
Range
|
290-400A
|
|