|
Load monitoring/limiting relay, 3-phase, range 15-50 A, manufacturer TENSE (Turkey)
The TRM-50 digital overload relay is designed to protect loads from damage caused by high currents, while also allowing operational control.
- 15-50 A (adjustable overload value)
- 50% fixed current asymmetry
- Adjustable fault delay time
- Adjustable operating mode (automatic, semi-automatic, manual)
- When you buy a TENSE current relay, you get a ready-to-use device - current transformers are included.
Device usage and operating principle
- Connect the device according to the attached wiring diagram.
- Once wiring is complete, connect the power supply. After switching on, the set values will be displayed on the screen for 5 seconds.
- Use the "A>" knob to set the overload value. The set value will be displayed on the left screen.
- Use the "t" knob to set the delay time. The set value will also be displayed on the left screen.
When the device is switched on:
- The relay switches on, the output contact switches to terminal 3 and the OUT indicator lights up.
- If the current exceeds the set overload value (A>), the device counts back the delay time and the ERR indicator lights up.
- Once the time has elapsed, the relay switches off, the contact switches to terminal 1 and the OUT indicator goes out.
The TRM-50 series electronic current relay is designed to automatically disconnect consumers when the maximum permissible current is exceeded. It has programmable switching range, switching time, and return settings. There are 3 modes for returning to "operating status" - MANUAL, SEMI-AUTO, AUTO.
Return modes
- Manual mode: To reset the device after an overload, press the Reset button. The corresponding LED will light up.
- Semi-automatic mode: Allows the device to automatically reset the system three times in case of overload, and then waits for a manual reset for the next fault. The corresponding LED will light up.
- Automatic mode: The device allows the system to automatically reset every time an overload fault occurs. The corresponding LED will light up.
Note: To change the mode, hold down the SELECT button for 10 seconds. When the mode is changed, the corresponding LED will light up.
Current asymmetry 50% (fixed)
If the difference between the highest and lowest current in the phases exceeds 50%, the device will enter asymmetry fault mode within 2 seconds (prevents system damage in case of single-phase loss).
If an asymmetry error occurs:
- The group of readings for the two phases that caused the fault will flash and the ERR indicator will light up.
- A manual reset is required to exit asymmetry fault mode.
Technical parameters
- Operating voltage: 150-260 VAC
- Operating frequency: 50/60 Hz
- Power consumption: <6 VA
- Operating temperature: -20 °C ... +55 °C
- Display: 3 × 3 digits, 5 LEDs
- Overload value (A>): 15-50 A
- Delay time: 0.1-20 s
- Connection type: clamp connection
- Contacts: 5 A / 250 V AC (active load)
- Cable diameter: 2.5 mm²
- Weight: max. 250 g
- Installation: DIN rail
- Maximum altitude: <2000 m
Note: TRM-50, TRM-100, TRM-200 and TRM-300 can only be used with the included current transformers. TRM-400 can be used with a 400/5 current transformer.
Basic
|
Manufacturer
|
Tense
|
|
Country of production
|
Turkey
|
|
Installation type
|
DIN rail mountable
|
|
Number of expansion contacts
|
1 pc.
|
|
Number of switching contacts
|
1 pc.
|
|
Cross-section of connected wires
|
2.5 mm²
|
|
Housing material
|
Plastic
|
|
View
|
Yes
|
|
Mass
|
250 g
|
|
On/off LED
|
Yes
|
|
"Overload" LED
|
Yes
|
|
Minimum storage temperature
|
-20 degrees.
|
|
Maximum storage temperature
|
55 degrees.
|
|
Protection level IP
|
30
|
|
Lifespan
|
10 years
|
|
Specifications
|
|
|
Number of phases
|
3
|
|
Rated operating voltage
|
220V
|
|
Rated current
|
5A
|
|
Current frequency
|
50 Hz
|
|
Rated power
|
3W
|
|
Minimum operating temperature
|
-20 degrees.
|
|
Maximum operating temperature
|
55 degrees.
|
|
Overall dimensions
|
|
|
Length
|
85 mm
|
|
Height
|
75 mm
|
|
Width
|
44 mm
|
|
User features
|
|
|
Delay time
|
0.1 s -20 (s)
|
|
Installation
|
DIN+screws
|
|
Range
|
15-50A
|
|