Electronic pulse counter / pulse counter

Barcode: DS-48
Regular price
€51,60
Regular price
Sale price
€51,60
excl. VAT: €43
Out of stock
  • Description
  • Instructions
  • Payment methods
  • Warranty

DS-48 pulse counter - 2× display, 2 inputs, relay output

Product description

The DS-48 pulse counter is a universal two-input panel counter equipped with two 4-digit LED displays (current value + target value). It can read, subtract, and process signals from mechanical switches, PNP/NPN inductive sensors, and incremental encoders. Thanks to a wide range of input and output functions, it is suitable for industrial automation systems, production lines, measuring stations, and process control.

Main features

  • 2× 4-digit 7-segment LED display

  • 1× OUT relay output + SSR output

  • Various modes: counting, counting, addition from multiple inputs, control via second input

  • Supports mechanical switches, PNP/NPN sensors, and encoders

  • Selectable input frequency: 20 / 50 / 2500 / 7500 Hz

  • Hesla setting protection

  • EEPROM memory - data retention during power failure

  • OFFSET and decimal point setting option

  • Automatic restoration of last value after power failure

Function

Input function (7 modes):

  • Count up

  • Countdown

  • Simultaneous addition from two inputs

  • Pause controlled by the second input

  • Input negation

  • Counting on rising/falling edge

  • Combinations: addition from one edge, subtraction from the other edge, negation, etc.

Output functions (9 modes):

  • Relay switching after target reached

  • Hold on RESET

  • Pulse output 0.1-999.9 s

  • Control via SSR output (NPN)

Technical parameters

Display and dimensions

  • Dimensions: 48 × 48 × 96 mm

  • Mounting hole: 44 × 44 mm

  • Display: 2 × 4-digit LED

Inputs

  • Number of inputs: 2

  • Input types: mechanical switch, PNP/NPN sensor, NPN/PNP/totem-pole encoder output.

  • Input voltage: 5-30 V

  • Maximum input frequency: 7500 Hz

  • Selectable frequencies: 20 / 50 / 2500 / 7500 Hz

  • Reset input: PNP, min. 10 ms, terminal 12

  • Sensor power: 12 VDC / 50 mA (max)

Outputs

  • 1× SPDT relay 250 VAC, 2 A (resistive load) - COM (4), NO (3), NC (5).

  • 1× SSR control (NPN, max. 100 mA, 30 V) - terminals 13 (SSout), 14 (GND).

Power supply

  • 100-240 V AC, 50/60 Hz

  • Power consumption: < 8 VA

Operating conditions

  • Operating temperature: -20 °C to +55 °C

  • Maximum altitude above sea level: 2000 m

Special features

  • EEPROM memory stores all settings and current values after power failure

  • Adjustable OFFSET count value

  • Password protection against unwanted parameter changes

  • Selectable decimal place (0 / 0.0 / 0.00 / 0.000)

Installation recommendations

  • Use shielded and twisted signal cables, ground the shielding

  • Separate signal wires from power and supply cables separately

  • Use a power supply input fuse F250 mA / 250 VAC.

  • Protect devices from moisture, vibration, dust, and extreme temperatures.

  • For mechanical switches, it is recommended to set the input frequency to 20 Hz.

  • When using two inputs:

  • Phs4 mode → max. ¼ input frequency

  • Modes 1u2u, 1u2d, Phs2 → max. ½ input frequency

Manual